2,872 research outputs found

    Characterizing the Load Environment of Ferry Landings for Washington State Ferries and the Alaska Marine Highway System

    Get PDF
    INE/AUTC 13.0

    Selecting asteroids for a targeted spectroscopic survey

    Full text link
    Asteroid spectroscopy reflects surface mineralogy. There are few thousand asteroids whose surfaces have been observed spectrally. Determining the surface properties of those objects is important for many practical and scientific applications, such as for example developing impact deflection strategies or studying history and evolution of the Solar System and planet formation. The aim of this study is to develop a pre-selection method that can be utilized in searching for asteroids of any taxonomic complex. The method could then be utilized im multiple applications such as searching for the missing V-types or looking for primitive asteroids. We used the Bayes Naive Classifier combined with observations obtained in the course of the Sloan Digital Sky Survey and the Wide-field Infrared Survey Explorer surveys as well as a database of asteroid phase curves for asteroids with known taxonomic type. Using the new classification method we have selected a number of possible V-type candidates. Some of the candidates were than spectrally observed at the Nordic Optical Telescope and South African Large Telescope. We have developed and tested the new pre-selection method. We found three asteroids in the mid/outer Main Belt that are likely of differentiated type. Near-Infrared are still required to confirm this discovery. Similarly to other studies we found that V-type candidates cluster around the Vesta family and are rare in the mid/oter Main Belt. The new method shows that even largely explored large databases combined together could still be further exploited in for example solving the missing dunite problem.Comment: accepted to A

    Gas gun shock experiments with single-pulse x-ray phase contrast imaging and diffraction at the Advanced Photon Source

    Full text link
    The highly transient nature of shock loading and pronounced microstructure effects on dynamic materials response call for {\it in situ}, temporally and spatially resolved, x-ray-based diagnostics. Third-generation synchrotron x-ray sources are advantageous for x-ray phase contrast imaging (PCI) and diffraction under dynamic loading, due to their high photon energy, high photon fluxes, high coherency, and high pulse repetition rates. The feasibility of bulk-scale gas gun shock experiments with dynamic x-ray PCI and diffraction measurements was investigated at the beamline 32ID-B of the Advanced Photon Source. The x-ray beam characteristics, experimental setup, x-ray diagnostics, and static and dynamic test results are described. We demonstrate ultrafast, multiframe, single-pulse PCI measurements with unprecedented temporal (<<100 ps) and spatial (∼\sim2 μ\mum) resolutions for bulk-scale shock experiments, as well as single-pulse dynamic Laue diffraction. The results not only substantiate the potential of synchrotron-based experiments for addressing a variety of shock physics problems, but also allow us to identify the technical challenges related to image detection, x-ray source, and dynamic loading

    Physical and dynamical characterisation of low Delta-V NEA (190491) 2000 FJ10

    Full text link
    We investigated the physical properties and dynamical evolution of Near Earth Asteroid (NEA) (190491) 2000 FJ10 in order to assess the suitability of this accessible NEA as a space mission target. Photometry and colour determination were carried out with the 1.54 m Kuiper Telescope and the 10 m Southern African Large Telescope during the object's recent favourable apparition in 2011-12. During the earlier 2008 apparition, a spectrum of the object in the 6000-9000 Angstrom region was obtained with the 4.2 m William Herschel Telescope. Interpretation of the observational results was aided by numerical simulations of 1000 dynamical clones of 2000 FJ10 up to 10^6 yr in the past and in the future. The asteroid's spectrum and colours determined by our observations suggest a taxonomic classification within the S-complex although other classifications (V, D, E, M, P) cannot be ruled out. On this evidence, it is unlikely to be a primitive, relatively unaltered remnant from the early history of the solar system and thus a low priority target for robotic sample return. Our photometry placed a lower bound of 2 hrs to the asteroid's rotation period. Its absolute magnitude was estimated to be 21.54+-0.1 which, for a typical S-complex albedo, translates into a diameter of 130+-20 m. Our dynamical simulations show that it has likely been an Amor for the past 10^5 yr. Although currently not Earth-crossing, it will likely become so during the period 50 - 100 kyr in the future. It may have arrived from the inner or central Main Belt > 1 Myr ago as a former member of a low-inclination S-class asteroid family. Its relatively slow rotation and large size make it a suitable destination for a human mission. We show that ballistic Earth-190491-Earth transfer trajectories with Delta-V < 2 km s^-1 at the asteroid exist between 2052 and 2061.Comment: 2 Tables, 11 Figures, accepted for publication in Astronomy & Astrophysic

    Batrachochytrium dendrobatidis Detected in Amphibians from National Forests in Eastern Texas, USA

    Get PDF
    The amphibian disease chytridiomycosis, caused by the pathogenic fungus Batrachochytrium dendrobatidis (Bd, Longcore et al. 1999), is well known as a major threat to amphibians resulting in mass die-offs and population declines throughout the world (Berger et al. 1998; Blaustein and Keisecker 2002; Daszak et al. 2003; McCallum 2005; Rachowicz et al. 2006). Batrachochytrium dendrobatidis has been detected on amphibians from sites across North America (Ouellet et al. 2005; Woodhams et al. 2008) and appears to be most prevalent in the western and the northeastern United States (Longcore et al. 2007; Schlaepfer et al. 2007). Whereas infected anurans also have been found throughout the southeastern US (Green and Dodd 2007), there have been no reports of Bd from amphibians in eastern Texas, a broad area encompassing 10,000,000 ha. We sampled amphibians for the presence of Bd in four National Forests in eastern Texas (approximately 31°N latitude)

    Haptoglobin genotype, haemoglobin and malaria in Gambian children

    Get PDF

    Phonocardiogram Segmentation with Tiny Computing

    Get PDF
    The stethoscope is a daily used tool that allows medical doctors to diagnose common cardiovascular diseases by listening to heart sounds. However, dedicated medical training is required to operate it. Numerous machine learning techniques have been used in attempts to automate this process and have yielded highly accurate results. However, creating a low power, portable, economical, and accurate machine learning stethoscope calls for tiny processing of phonocardiograms i.e., heart sound digital processing to run within an embedded device. To address the need to deploy the solution within a constrained tiny device, we propose an 8-bit deep learning model with low embedded FLASH and RAM utilization of 126 KiB and 45 KiB respectively, which is optimized for inference on an off-the-shelf STM32H7 microcontroller with an inference time of 12 ms, in 126KiB FLASH and 45 KiB RAM being 91.65% accurate

    Hammerhead, an ultrahigh resolution ePix camera for wavelength-dispersive spectrometers

    Full text link
    Wavelength-dispersive spectrometers (WDS) are often used in synchrotron and FEL applications where high energy resolution (in the order of eV) is important. Increasing WDS energy resolution requires increasing spatial resolution of the detectors in the dispersion direction. The common approaches with strip detectors or small pixel detectors are not ideal. We present a novel approach, with a sensor using rectangular pixels with a high aspect ratio (between strips and pixels, further called "strixels"), and strixel redistribution to match the square pixel arrays of typical ASICs while avoiding the considerable effort of redesigning ASICs. This results in a sensor area of 17.4 mm x 77 mm, with a fine pitch of 25 μ\mum in the horizontal direction resulting in 3072 columns and 176 rows. The sensors use ePix100 readout ASICs, leveraging their low noise (43 e−^-, or 180 eV rms). We present results obtained with a Hammerhead ePix100 camera, showing that the small pitch (25 μ\mum) in the dispersion direction maximizes performance for both high and low photon occupancies, resulting in optimal WDS energy resolution. The low noise level at high photon occupancy allows precise photon counting, while at low occupancy, both the energy and the subpixel position can be reconstructed for every photon, allowing an ultrahigh resolution (in the order of 1 μ\mum) in the dispersion direction and rejection of scattered beam and harmonics. Using strixel sensors with redistribution and flip-chip bonding to standard ePix readout ASICs results in ultrahigh position resolution (∼\sim1 μ\mum) and low noise in WDS applications, leveraging the advantages of hybrid pixel detectors (high production yield, good availability, relatively inexpensive) while minimizing development complexity through sharing the ASIC, hardware, software and DAQ development with existing versions of ePix cameras.Comment: 8 pages, 6 figure
    • …
    corecore